Standard Industrial Modbus TCP/RTU/ASCII Network Integration PLANET has added the Industrial Modbus TCP/IP Protocol to its easily-integrated industrial management level products that come with SCADA/HMI system and other data acquisition systems on factory floors. Moreover, the industrial IT SNMP network is upgraded to the Industrial automation Modbus TCP/IP network. PLANET industrial management level products with the Modbus TCP/IP Protocol offer flexible network connectivity solutions for the industrial automation environment.
To complete the industrial automation environment application solution, PLANET has announced a first industrial level 1-port RS232/422/485 Modbus Gateway, IMG-2105AT, a bridge that converts between Modbus TCP/IP Protocol and Modbus RTU/ASCII Protocol. It features a wide operating temperature range from -40 to 75 degrees C and a compact but rugged IP30 metal housing.
A Conversion Bridge for Flexible Network Deployment The IMG-2105AT can be a conversion bridge between the equipment with the Modbus RTU/ASCII Protocol and the administrator workstations that run the Modbus TCP/IP Protocol. The RS232/422/485 serial interface of the IMG-2105AT provides the Modbus RTU/ASCII operation mode and various baud rate options to meet the demand of integration between the Modbus TCP/IP Protocol, Modbus RTU Master/Slave Protocol and Modbus ASCII Master/Slave Protocol.
The advantage of having the IMG-2105AT is to assist users to build an industrial environment between the Modbus TCP/IP Protocol and the Modbus RTU/ASCII Protocol easily, thus offering an application solution to the industrial control equipment without Ethernet ports and the industrial control equipment can only control through an industrial PC workstation or industrial control panel.
In addition, the effective integration solution of Modbus Ethernet devices, Modbus serial equipment or multi Modbus master / slave in an industrial hybrid network brings the following: - Master mode supports up to 32 TCP slave connection requests - Slave mode supports up to 32 TCP master connections
Remote Management The IMG-2105AT makes the connected industrial Modbus RTU/ASCII equipment become IP-based facilities and is able to connect to the Modbus TCP/IP network via its RS232/422/485 serial interface and 10/100BASE-TX RJ45 Ethernet port. It provides a remote web management and telnet Interface for efficient remote network management. The IMG-2105AT also provides PLANET Modbus Gateway utility tool and supports PLANET Smart Discovery utility to help network administrator to easily get the current IP subnet address information or change the IP subnet address setting of the IMG-2105AT.
Modbus Serial Port State Monitoring The IMG-2105AT shows the details of the total bytes transmitted and received on the RS232/422/485 serial interface, and the detailed total number of frames transmitted and received on the remote web/telnet management interface. This function allows network administrator to check the status and statistics of the IMG-2105AT via the single RS232/422/485 serial interface.
Stable Performance in Hardened Environment Design The IMG-2105AT provides a high level of immunity against electromagnetic interference and heavy electrical surges which are usually found on plant floors or in curb-side traffic control cabinets. Its operating temperature ranging from -40 to 75 degrees C allows the IMG-2105AT to be placed in almost any difficult environment.
The IMG-2105AT is equipped with a compact IP30-rated metal case that allows wall mounting for efficient use of cabinet space. The IMG-2105AT also provides an integrated power supply source with wide-ranging voltages (9 to 48V DC / 24V AC) ideally suitable for worldwide operation with high availability applications.
Dual Power Input for High Availability Network System The IMG-2105AT features a strong dual power input system with wide-ranging voltages (9V~48V DC / 24V AC) incorporated into customer’s automation network to enhance system reliability and uptime. In the example below, when Power Supply 1 fails to work, the hardware failover function will be activated automatically to keep powering the IMG-2105AT via Power Supply 2 without any break of operation.
Extending Distance The IMG-2105A is able to extend the distance of deploying serial equipment and hosts. The selectable fiber-optic cables on the basis of distance are provided. Therefore, this product will perfectly satisfy the diverse demands while providing reliable and efficient network solutions based on the distance and budgets of installation.
Tuotteen väri
Sininen
LED-merkkivalot
Kyllä
International Protection (IP)-koodi
IP30
Ohjaus- ja näyttöyksikkö
Ei
Ethernet LAN -datanopeudet
100 Mbit/s
Verkkostandardit
IEEE 802.3, IEEE 802.3u
RS-232-portit
1
Kiinteiden FSP-porttine lukumäärä
1
Sarjaliitännän tyyppi
RS-232/422/485
Syslog
Kyllä
Tehovaatimukset
9〜48V DC / 24V AC
Tuotteen leveys
32 mm
Tuotteen syvyys
87,8 mm
Tuotteen korkeus
135 mm
Paino
390 g
Käyttölämpötila (T-T)
40 - 75 °C
Varastointilämpötila
40 - 85 °C
Käytön suhteellinen kosteus (H-H)
5 - 95%
Löydämme tuotteen järjestelmästämme helposti seuraavalla tuotenumerolla
EAN:
4711605285131
SKU:
IMG-2105AT
Miksi samalla tuotteella on monta eri tuotesivua tai tuotenumeroa?